| Issued | Violation | Type | Category | Description | Disposed |
|---|---|---|---|---|---|
| Jul 17, 2026 | CER02CM | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | REQUESTING AN ENGINNERS REPORT DUE TO CHARRED JOISTS SECTIONS OF ROOF OPEN AND WATER DAMAGE THROUGHOUT DUE TO FIRE. A... | — |
| Jul 17, 2026 | CER01CM | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURE RENDERED NON COMPLIANT. AT TIME OF INSPECTION RESPONDING TO AN INCIDENT OBSERVED BUILDING SUSTAINED DAMAGES... | — |
| Apr 24, 2024 | CE41202ML | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | UNPERMTD MASS EXCAVTN 12"- 19" BELOW CELLAR OBSRVD UNDERMINNG FOOTINGS @EXP#1&3&PARTY WALS@EXP#2&4.EXCVTN WRK RESULT ... | — |
| Apr 24, 2024 | CE41201ML | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | UNPERMTD MASS EXCAVTN 12"- 19" BELOW CELLAR OBSRVD UNDERMING FOOTINGS @EXP#1&3&PARTY WALS@EXP#2&4.EXCVTN WRK RESULT I... | — |
| Feb 28, 2024 | CE41202ML | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | UNPERMTD MASS EXCAVTN 12"- 19"BELOW CELLAR OBSRVD UNDERMINNG FOOTINGS@ EXP#1&3&PARTY WALS@EXP#2&4.EXCVTN WRK RESULT I... | — |
| Feb 28, 2024 | CE41201ML | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | UNPERMTD MASS EXCAVTN 12"- 19"BELOW CELLAR OBSRVD UNDERMINNG FOOTINGS@ EXP#1&3&PARTY WALS@EXP#2&4.EXCVTN WRK RESULT I... | — |
| Feb 23, 2024 | CE41201ML | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | EMERGENCY WORK-UNPERMITTED CONSTRUCTION WORK CONSISTING OF 15"-19" EXCAVATION BELOW THE BOTTOM OF FOOTING ELEVATION A... | — |
| Feb 23, 2024 | E41201ML | C-CONSTRUCTION OTHER OPTIONAL | VW*-VIOLATION - WORK W/O PERMIT DISMISSED | EMERGENCY WORK-UNPERMITTED CONSTRUCTION WORK CONSISTING OF 15"-19" EXCAVATION BELOW THE BOTTOM OF FOOTING ELEVATION A... | Mar 13, 2024 |
| Feb 22, 2024 | 24-00420 | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | OBSERVED EXCAVATION/ UNDERPINNING AT CELLAR LEVEL. UNDERPINNING WAS DONE AT EXPOSURE #2, 3 AND 4 WITH FRESH CONCRETE ... | — |