ECB violations
201 Street, Queens • Block 11018 • Lot 0021
87 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 30, 2008 | 34712208X | RESOLVE | CLASS - 2 | REISSUE: 34712207X. ENTRY ABOVE DOORWAY INTO THE ELECTRICAL ROOM IS NOT FIRE RATED.METAL GRILL WITH HOLES AT CELLAR L... | $0 | $0 | Dec 16, 2008 |
| Oct 30, 2008 | 34712211R | RESOLVE | CLASS - 2 | ROOF HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE BLDG CAUSING INTERIOR DAMAGES IN ROOM 9A. REMEDY:REPAIR//REPLAC... | $0 | $0 | Jan 6, 2009 |
| Oct 30, 2008 | 34712210P | RESOLVE | CLASS - 2 | REISSUE: 34563998N. CONCRETE BLOCK WALL IS CRACKED VERTICALLY IN ROOM M15 APPROXIMATELY 2' FEET LONG. REMEDY:REPAIR/R... | $0 | $0 | Dec 16, 2008 |
| Oct 30, 2008 | 34712206M | RESOLVE | CLASS - 2 | REISSUE:34563992M. WINDOW LINTEL ABOVE THE MAIN ENTRANCE IS ROTTEN, SAGGING & RUSTED ON THE 2ND FLOOR LEVEL. REMEDY:R... | $0 | $0 | Dec 16, 2008 |
| Mar 15, 2007 | 34563995H | RESOLVE | Non-Hazardous | PLACE OF ASSEMBLY EXIT DOORS,SWING AGAINST THE FLOW OF EGRESS CAFETERIA DOOR LEADING INTO CORRIDORS, SWING INTO CAFET... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563998N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-INTERIOR.STRUCTURAL CRACK APPROX 1/4"WIDE.RUNNING FROM CEILING TO APPROX 4'-0"AFF.)CRACK IS THROU... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563992M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-EXTERIOR.REISSUE # 34481994R.SPALLING SPLITTING DECORATIVE STONE WORK & SAGGING LINTELS BELOW 3RD... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563994X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN - INTERIOR ELECTRIC ROOM - OPEN GRATING OFFER DOORBREACHING THE HOURLY RATING NEEDED IN THE ELECT... | $0 | $0 | Jun 26, 2007 |
| Mar 15, 2007 | 34563997L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-INTERIOR.CORRIDOR CEILING TILE & GRID SYSTEM DAMAGED BY WATER FROM ROOF LEAK.REMEDY:REPLACE TILE ... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563993Y | RESOLVE | Non-Hazardous | EXIT DOOR NOT SELF CLOSING.DOOR THAT ARE MISSING, OR HAVE BROKEN CLOSERS.1FL-EXIT 5-2 DOORS,EXIT 7-1 DOORS,EXIT 9 EXI... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563990Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-INTERIOR.REISSUE # 34481993P,34519117X.CELLAR-CRACKED, SPALLING CONCRETE BEAMS AT BOILER ROOM SOU... | $0 | $0 | May 8, 2007 |
| Mar 15, 2007 | 34563991K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN-INTERIOR. REISSUE # 34375070H,34519116Y,34281554R.VERTICAL CRACK IN GYM ALL FOUR COLUMNS.REMEDY:R... | $0 | $0 | May 8, 2007 |
| Apr 11, 2006 | 34519118H | RESOLVE | Hazardous | REISSUE VI 34481994R SPALLING,SPLITTING DECORATIVE STONE WORK & SAGINGLENTELS BELOW 3RD FL (STONE WORK) LINTELS OVER ... | $0 | $0 | Aug 15, 2006 |
| Apr 11, 2006 | 34519116Y | RESOLVE | Hazardous | REISSUE VI 34375070H VERTICAL CRACKS IN GYM ALL 4 COLUMNS.REMEDY:REPAIR DEFECT | $0 | $0 | Aug 15, 2006 |
| Apr 11, 2006 | 34519117X | RESOLVE | Hazardous | REISSUE VI 34481993P CRACK SPALLING CONCRETE CEILING & I BEAMS LOCATION BOILER ROOM SOUTHWALL & STORAGE ROOM NORTHSID... | $0 | $0 | Aug 15, 2006 |
| May 15, 2005 | 34481994R | RESOLVE | Hazardous | SPALLING SPLITTING DECORATIVE STONE WEEK & FAILING SAGGING LINTELS LOCATIONS:EAST FACADE BELOW 3RD FLOOR WINDOWS (STO... | $0 | $0 | Aug 16, 2005 |
| May 5, 2005 | 34481992N | RESOLVE | Non-Hazardous | WATER PENETRATION THROUGH EXTERIOR WALLS LOCATION:AT EXHAUST OVER EXIT# 4 VESTIBLE (EXIT TO REAR YARD)OVER N/E EXIT D... | $0 | $0 | Aug 16, 2005 |
| May 5, 2005 | 34481993P | RESOLVE | Hazardous | CRACKED & SPALLING CONCRETE @ CEILINGS & I BEAMS LOCATIONS BOILER ROOM@ SOUTH WALL (OPPOSITE BOILER)AND IN SMALL STOR... | $0 | $0 | Aug 16, 2005 |
| Jan 8, 2004 | 34422055Z | RESOLVE | Non-Hazardous | EXIT DOOR SWINGS AGANIST EXIT # 3 OPENS AGANIST THE FLOW OF EGRESS FROM STAIRCASE.REMEDY:REPAIR/REPLACE DOOR. | $0 | $0 | Mar 30, 2004 |
| Jan 8, 2004 | 34422056K | RESOLVE | Non-Hazardous | EXIT DOORS SWINGS AGAINST THE FLOW OF EGRESS NOTED DOUBLE DOOR IN CORRIDOR BETWEENS ROOMS 119 AND 120 SWING AGANIST T... | $0 | $0 | Mar 30, 2004 |
| Feb 11, 2003 | 34375069K | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTED; IN ROOM 321 DUE TO SUSTAINED WATER DAMAGE APPROX 2' ROUND SECTION OF CEILING SPALLED, PEE... | $0 | $0 | Apr 22, 2003 |
| Feb 11, 2003 | 34375068Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN. NOTED AT ROOF TWO 3'X4' FENCE PANELS BROKEN OFF 2 OR 4 HINGES IN DANGER OF FALLING FROM BUILDING... | $0 | $0 | Apr 22, 2003 |
| Feb 11, 2003 | 34375070H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. NOTED; IN GYMNASIUM ON BOTH EAST AND WEST WALLS APPROX 6' TO 15' VERTICAL STRUCTURAL CRACK ON CO... | $0 | $0 | Apr 22, 2003 |
| Apr 5, 2001 | 34279895M | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY LIGHT FIXTURE WITHIN ALL CORRIDOR AND STAIR INCLUDING AUDITORIUM,CAFETERIA AND GYM ON FL... | $0 | $0 | May 22, 2001 |
| Apr 5, 2001 | 34279896Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY LIGHT FIXTURE WITHIN ALL CORRIDOR.THROUGH OUT THE BUILGING.FAILURE TO PROVIDE EMERGENCY ... | $0 | $0 | May 22, 2001 |
| Feb 26, 2001 | 34281553P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN.UPON INSPECTION OF THE ABOVE ADDRESS.THE FOLLOWING ROOM'S HAVE SPALLING PLASTER ON WALLS AND CEIL... | $0 | $0 | May 8, 2001 |
| Feb 26, 2001 | 34281556K | RESOLVE | Non-Hazardous | PLACE OF ASSEMBLY EXIT DOOR SWINGS AGAINST THE FLOW OF EGRESS.UPON INSPECTION OF THE ABOVE ADDRESS(1)CAFETERIA DOORS(... | $0 | $0 | May 8, 2001 |
| Feb 26, 2001 | 34281555Z | RESOLVE | Non-Hazardous | NO PANIC HARDWARE IN PLACE OF ASSEMBLY.UPON INSPECTION OF THE ABOVE ADDRESS THE FOLLOWING P.O.A.HAVE NO PANIC HARDWAR... | $0 | $0 | May 8, 2001 |
| Feb 26, 2001 | 34281554R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN UPON INSPECTION OF THE ABOVE ADDRESS.(1)GYNASIUM HAS STRESS CRACKS IN TWO COLUMNS,AT EAST SIDE OF... | $0 | $0 | May 8, 2001 |
| Feb 26, 2001 | 34281552N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN UPON INSPECTION OF THE ABOVE ADDRESS(1)ALL THREE(3)EXUAST HOUSING'S ON ROOF,HAVE STRESS CRACK'S I... | $0 | $0 | May 8, 2001 |
| May 1, 2000 | 34241221M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING:DEFECTS ARE:PAVED SURFACE IN PLAY YARD ISUNDULATING,CRACKED,WITH SINK HOLES CRACK ON WAL... | $0 | $0 | Aug 22, 2000 |
| May 1, 2000 | 34241220K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING:DEFECTS ARE VERTICAL CRACK ON S.E.AND SW WALLS IN GYM @ 3FL.CRACKED CEILING IN RM 305.PE... | $0 | $0 | Aug 22, 2000 |
| Apr 5, 1999 | 34198773J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. DEFECT IS: ASPHALT PAVEMENT HAS DEVELOP-ED CRACKS AND POT HOLES THROUGHOUT PLAYGROUND. ... | $0 | $0 | May 25, 1999 |
| Feb 16, 1999 | 34198708N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT: ENTIRE BLDG CRUMBLING & MISSING MORTAR ALLOWING WATER TO PENETRATE THROUGH WALLS INTO IN... | $0 | $0 | May 25, 1999 |
| Feb 16, 1999 | 34198710M | RESOLVE | Non-Hazardous | NEW BLDG OCCUPANCIES W/O A VALID C OF O. REMEDY: OBTAIN C OF O. | $0 | $0 | May 25, 1999 |
| Feb 16, 1999 | 34198709P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT: NO EMERGENCY LIGHTING IN STAIRWELLS OR ANY OTHER PART OF BLDG, INCLUDING TRANSPORTABLE (... | $0 | $0 | May 25, 1999 |
| Feb 16, 1999 | 34198707L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT: ENTRANCE STEPS BLUE STONE SETTLED, CHAINLINK AT REAR OF BLDG FALLEN & DETERIORATED, ASHP... | $0 | $0 | May 25, 1999 |