Issued Class Status Violation Apartment Correct by
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
I INFO NOV SENT OUT §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT WEST WINDOW IN THE 4th ROOM FROM ... PH Feb 21, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES : IN THE ENTIRE APARTMENT LOCATED... PH Feb 21, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES : IN THE ENTIRE APARTMENT LOCATED ... PH Feb 21, 2015
Feb 13, 2015 C VIOLATION DISMISSED SECTION 27-2028, 2032 ADMIN.CODE: PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM OR AN AP... PH Feb 7, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... NORTH AND WEST WALLS AT... PH Feb 21, 2015
Feb 13, 2015 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... PH Mar 20, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT BOILER ROOM IN CELLAR Feb 21, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... WALLS APPROX, 360 SQ. F... Feb 21, 2015
Feb 13, 2015 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE REAR ENTRANCE DOOR TO CELLAR Feb 21, 2015
Sep 30, 2013 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING CONSISTING OF DOUBLE CYLINDER LOOK INSTALLED AT METAL DOOR ... 1FL Oct 8, 2013
Sep 30, 2013 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... 1FL Nov 4, 2013
Sep 30, 2013 C VIOLATION DISMISSED SECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE RANG IN THE KITCHEN LOCATED AT ... 1FL Oct 8, 2013
Sep 30, 2013 C VIOLATION CLOSED SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, ... 1FL Sep 27, 2013
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND C... 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW GLASS WEST BEDROOM LOCATED AT APT 1FL, 1... 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALLS. IN THE... 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB, NORTH BATHROOM LOCATED AT APT 1FL, 1s... 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW SASH NORTH BATHROOM LOCATED AT APT 1FL, ... 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SOUTH BATHROOM LOCATED AT APT 1FL, 1st STORY 1FL Dec 13, 2012
Nov 8, 2012 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... 1FL Dec 13, 2012
Nov 8, 2012 A VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ALL INTERIOR DOORS IN THE ENTIRE APARTMENT LOCA... 1FL Feb 11, 2013
Nov 8, 2012 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK ON BOTH INTERIOR AND EXTERIOR DOORS IN... 1FL Nov 14, 2012
Oct 1, 2012 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1FL,... 1FL Nov 5, 2012
Oct 1, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES IN THE ... 1FL Nov 5, 2012
Oct 1, 2012 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS PANE AT UPPER WAINDOW SASH IN THE 2nd ROOM FROM NORTH... 1FL Nov 5, 2012
Oct 1, 2012 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... 1FL Nov 5, 2012
Oct 1, 2012 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK IN THE ENTRANCE LOCATED A... 1FL Oct 7, 2012
Oct 1, 2012 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHTUB FAUCET IN THE BATHROOM IN THE 1st ROOM... 1FL Nov 5, 2012
Sep 28, 2012 A VIOLATION CLOSED SECTION 27-2027 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE GUTTER FRONT SECTION AT ROOF Jan 1, 2013
Jan 4, 2012 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE WASHBASIN IN THE BATHROOM LOCATED AT... 2 Feb 8, 2012
Nov 10, 2011 B VIOLATION CLOSED SECTION 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CON... Dec 15, 2011
Apr 13, 2011 B VIOLATION CLOSED SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACC... 1FL May 18, 2011
Apr 13, 2011 B VIOLATION CLOSED SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st STORY 1FL May 18, 2011
Apr 13, 2011 B VIOLATION CLOSED SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st... 1FL May 18, 2011
Apr 13, 2011 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS & CEI... 1FL May 18, 2011
Apr 13, 2011 C VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT FRONT ENTRANCE DOOR LO... 1FL Apr 19, 2011
Apr 13, 2011 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR AT NORTH/WEST ROOM. LOCATED AT APT... 1FL May 18, 2011
Mar 22, 2011 B VIOLATION CLOSED SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND C... 1 Apr 26, 2011
Mar 22, 2011 B VIOLATION CLOSED SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st S... 1 Apr 26, 2011
Mar 22, 2011 B VIOLATION CLOSED SECTION 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATH-TUB IN THE BATHROOM LOCATED AT APT 1, 1st... 1 Apr 26, 2011
Mar 22, 2011 B VIOLATION CLOSED SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY 1 Apr 26, 2011