HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| May 7, 2026 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Aug 10, 2026 |
| — | I | INFO NOV SENT OUT | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Apr 15, 2024 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 19, 2024 |
| — | I | INFO NOV SENT OUT | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Mar 29, 2023 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 2, 2023 |
| — | I | INFO NOV SENT OUT | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| — | I | NOT COMPLIED WITH | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Mar 4, 2022 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jun 7, 2022 |
| Nov 24, 2021 | B | VIOLATION CLOSED | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND ... | — | Dec 29, 2021 |
| Nov 24, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH NEW THE BROKEN, DEFECTIVE AND/OR MISSING DROP LADDER | — | Nov 30, 2021 |
| Nov 24, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS .. | — | Nov 30, 2021 |
| Jul 12, 2021 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST ... | 1 | Aug 16, 2021 |
| Jul 12, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT PLASTER AT CEILING AT... | — | Jul 18, 2021 |
| Jul 12, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING FIREPROOF DOOR AT BOILER ROOM | — | Jul 18, 2021 |
| Jul 12, 2021 | B | FIRST NO ACCESS TO RE- INSPECT VIOLATION | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). - MISSING LOCATED AT APT 1, 1st STORY, 1s... | 1 | Aug 16, 2021 |
| Jul 12, 2021 | C | VIOLATION CLOSED | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 1 | Aug 7, 2021 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Apr 15, 2021 | A | FIRST NO ACCESS TO RE- INSPECT VIOLATION | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 19, 2021 |
| Dec 19, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING AIR VALVE AT EAST WALL RADIATOR IN THE 1st ROOM FROM EAST AT SOUTH LO... | 3FL | Dec 27, 2019 |
| Dec 19, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BOILER AT BOILER ROOM | — | Dec 27, 2019 |
| — | I | NOT COMPLIED WITH | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Jul 22, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR AT PUBLIC HALL,... | — | Oct 25, 2019 |
| Jul 22, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD TREADS AT 7TH ,8TH ,9TH , AND 10TH FROM BOTTOM AT PU... | — | Aug 26, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS IN THE EN... | 2 | Oct 15, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH SPRING BALANCE AT NORTH WALL IN THE KITCHEN LO... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 1st ROOM... | 3 | Oct 15, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN TH... | 3 | Oct 15, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS IN THE EN... | 3 | Oct 15, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, ... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ELECTRIC PANEL BOX COVER IN THE PRIVATE HALLWAY LOCATED AT APT 3, 3rd... | 3 | Jul 20, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST AND SOUTH WALLS IN THE BATHROOM LOC... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 3rd ROOM... | 3 | Oct 15, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH SPRING BALANCE AT SOUTH WALL IN THE 3rd ROOM F... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 3rd ROOM... | 3 | Oct 15, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW FRAME OFFSET #1 AT SOUTH WALL IN THE 3rd ROOM FROM... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW FRAME OFFSET#1 AT SOUTH WALL IN THE 3rd ROOM FROM ... | 3 | Aug 16, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SHINGLES AT ROOF | — | Aug 16, 2019 |
| Jul 12, 2019 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE 3rd ROOM... | 2 | Oct 15, 2019 |
| Jul 12, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 2 | Jul 20, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHRO... | 2 | Aug 16, 2019 |
| Jul 12, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE K... | 2 | Jul 20, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, ... | 2 | Aug 16, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 2 | Aug 16, 2019 |
| Jul 12, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD TREADS AT 2ND ,6TH, 9TH ,10TH ,11TH AND 12TH FROM BO... | — | Jul 20, 2019 |
| Jul 12, 2019 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SHINGLES AT ROOF , 2nd STORY | — | Jul 20, 2019 |
| Jul 12, 2019 | C | NOT COMPLIED WITH | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANTS MATERIALS AT CEILING... | — | Jul 20, 2019 |
| Jul 12, 2019 | B | NOT COMPLIED WITH | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING STAIR HAND RAIL AT CELLAR | — | Aug 16, 2019 |
| Jul 12, 2019 | B | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Aug 16, 2019 |
| — | I | INFO NOV SENT OUT | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESU... | — | — |