ECB violations
147 Beach 116 Street • Block 16226 • Lot 0025
23 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 2, 2020 | 35480797J | RESOLVE | CLASS - 1 | BC3307.4 WORK & STORAGE ZONE.NOTE:AT THE TIME OF MY INSPECTION OF A 8 STORY NEW BLDG I OBSERVED FROM STREET LEVEL MAT... | $0 | $0 | Jun 16, 2020 |
| Oct 18, 2019 | 35458660H | RESOLVE | CLASS - 2 | POSTING OF UNLAWFUL SIGNS INFORMATION,PICTORIAL REPRESENTATION,BUSINESS OR ADVERTISING MESSAGES ON PROTECTIVE STRUCTU... | $0 | $0 | Dec 31, 2019 |
| Oct 18, 2019 | 35458661J | RESOLVE | CLASS - 2 | SEC. 3307.6.5.5 CLEANING OF THE DECKS OF SIDEWALK SHED. AT THE TIME OFMY INSPECTION IT WAS OBSERVED AN ACTIVE CONSTRU... | $0 | $0 | Dec 31, 2019 |
| Oct 18, 2019 | 35461790N | RESOLVE | CLASS - 2 | BC3301.6 DESOGN DRAWING REQUIRED BY CHAPTER 33 @THE TIME MY INSPECTIONIT WAS OBSERVED AN ACTIVE CONSTRUCTION SITE WIT... | $0 | $0 | Feb 11, 2020 |
| Oct 7, 2019 | 38271561L | RESOLVE | CLASS - 2 | CEASE USE 26-X-10. TOP EMERGENCY EXIT COVER SWITCH 19 NOT OPERATIVE. THIS IS A SAFETY DEVICE TO ENSURE (ELEVATOR) HOI... | $312 | $0 | Jan 28, 2020 |
| Apr 26, 2019 | 35402782N | RESOLVE | CLASS - 2 | 3303.4.2CONTAINERS WITH DEBRIS.AT THE TIME OF MY INSPECTION OF AN 8 STORY BLD.AT ROOF LEVEL WITH CONSTRUCTION OPERATI... | $0 | $0 | Jul 2, 2019 |
| Apr 26, 2019 | 35402779M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES(GUARDRAILS)AT THE TIME OF MY INSPECTION OF AN 8 STORY BLD.AT ... | $2,500 | $0 | Dec 10, 2019 |
| Apr 26, 2019 | 35402780J | RESOLVE | CLASS - 1 | 3303.8 STAND PIPE NOT IN READINESS.AT THE TIME OF MY INSPECTION OF AN 8 STORY BLD.AT ROOF LEVEL WITH CONSTRUCTION OPE... | $625 | $0 | Dec 10, 2019 |
| Apr 26, 2019 | 35402781L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.AT THE TIME OF MY INSPECTIONOF AN 8 STORY BLD.AT ROOF LEVEL WITH CONSTRUCTI... | $625 | $0 | Dec 10, 2019 |
| Apr 26, 2019 | 35402778K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE OR DESIGNATE SUPER/COMPETENT PERSON AS REQUIRED.AT THE TIME OF MY INSPECTION OF AN 8 STORY BLD.AT ... | $10,000 | $0 | Dec 10, 2019 |
| Jan 8, 2019 | 35377007K | RESOLVE | CLASS - 1 | BC3314.3.4/LOAD IMPOSED.NOTE;AT THE TIME OF MY INSPECTIOON OF A 8 STORY BUILDING AT ROOF LEVEL CONSTRUCTION WORK IN P... | $2,500 | $0 | Mar 19, 2019 |
| Jan 8, 2019 | 35377005R | RESOLVE | CLASS - 2 | BC3308.6.1.4/HORIZONTAL SAFETY NETTING SYSTEM.NOTE:AT THE TIME OF MY INSPECTION OF A 8 STORY BUILDING AT ROOF LEVEL A... | $625 | $0 | May 10, 2019 |
| Jan 8, 2019 | 35377006Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.INSTITUTE MAINTAIN SAFETY EQUIPMENT ... | $2,500 | $0 | May 10, 2019 |
| Dec 31, 2018 | 35354559R | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AT TIME OF INSPECTION I OBSERVED VE... | $400 | $0 | Mar 12, 2019 |
| Dec 24, 2018 | 35354541Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS#3314.1.AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD IN... | $2,400 | $0 | Jul 23, 2019 |
| Dec 24, 2018 | 35354540R | RESOLVE | CLASS - 2 | PEDESTRIAN PROTETCION DOES NOT MEET CODE SPECIFICATIONS#3307.6.4.4.AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED AND... | $2,400 | $0 | Jul 23, 2019 |
| Nov 23, 2018 | 35368365X | RESOLVE | CLASS - 2 | PROJECT INFO PANEL NOT PROVIDED SW SHED PARAPET PANEL 8 STY NEW BLDG UNDER CONSTRUCTION,IN ACTIVE JOB SITE AT THE TIM... | $0 | $0 | Jan 29, 2019 |
| Nov 15, 2018 | 35368661K | RESOLVE | CLASS - 1 | BC 1906.6.1.2 FAILURE TO SECURE RESHORES IN PROXIMITY TO THE FACADE AS NOTED: AT TIME OF INSPECTION ACTIVE SITE I OBS... | $2,500 | $0 | Jul 9, 2019 |
| Aug 24, 2018 | 35319434J | RESOLVE | CLASS - 2 | FAILURE TO HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE AS REQUIRED. AS NOTED: AT TIME OF MY INSPECTION (ACTIVE C... | $2,500 | $0 | Dec 18, 2018 |
| Aug 2, 2018 | 35345247N | RESOLVE | CLASS - 2 | BC3301.2 FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT. AT TIME OF INSPECTION OF AN ACTIVE JOB SITE, I OBSERVED ... | $0 | $0 | Oct 23, 2018 |
| Aug 2, 2018 | 35345249R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE, I OBSERVED REBAR AND CONSTRU... | $0 | $0 | Feb 5, 2019 |
| Aug 2, 2018 | 35345248P | RESOLVE | CLASS - 1 | BC3309.1 OVERHEAD PROTECTION ADJACENT PROPERTY. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE, OBSERVED CONCRETE DECKING... | $0 | $0 | Feb 5, 2019 |
| Mar 18, 2010 | 34842725J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. PARTIAL COLLAPSEDFENCE APPROX 60 LINEAR FEET LONG UNTO STREET SI... | $0 | $0 | Sep 14, 2010 |