ECB violations
140 Beach 119 Street, Queens • Block 16228 • Lot 0035
21 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 3, 2024 | 39126499P | RESOLVE | CLASS - 2 | REPAIR AND RESTORE TO SERVICE. | $0 | $0 | Dec 10, 2024 |
| Oct 5, 2022 | 39071470X | ACTIVE | CLASS - 2 | 1. THE ELEVATOR IN SECTION OF BUILDING OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREA... | $625 | $30 | Nov 20, 2023 |
| Jul 25, 2022 | 39066579N | ACTIVE | CLASS - 1 | 1 . THE ELEVATOR IN BUILDING OUT OF SERVICE. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZ... | $1,250 | $0 | Jan 17, 2023 |
| May 14, 2021 | 39041217P | RESOLVE | CLASS - 2 | REPAIR AND RESTORE TO SERVICE | $625 | $0 | Nov 9, 2021 |
| Sep 11, 2020 | 39028489M | RESOLVE | CLASS - 1 | NO STORAGE IN BOILER ROOM, COVERS MISSING ON CONTROLS, CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF C... | $1,250 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028490J | RESOLVE | CLASS - 1 | NO STORAGE IN BOILER ROOM, COVERS MISSING FROM CONTROLS CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF ... | $1,250 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028486R | ACTIVE | CLASS - 2 | BOILER UNREGISTERED, NO STORAGE IN BOILER ROOM, DISCHARGE PIPES MISSING ON WATER HEATERS RELIEF VALVES COVERS MISSING... | $625 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028487Z | ACTIVE | CLASS - 2 | COVER MISSING FROM CONTROL, RATING PLATE FOR BOILER INFORMATION UNREADABLE, CORRECT ALL VIOLATING CONDITIONS AND SUBM... | $625 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028491L | ACTIVE | CLASS - 2 | RATING PLATE ON BOILER UNREADABLE, BOILER ROOM SIGN ON DOOR MISSING, CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CE... | $625 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028492N | ACTIVE | CLASS - 1 | FOUND PEERLESS PSC-06 SER# 5117448-2015 GAS FIRED BOILER INSTALLED WITHOUT A PERMIT,, OBTAIN PERMIT; OBTAIN PROPER PE... | $2,500 | $0 | Feb 8, 2022 |
| Sep 11, 2020 | 39028488K | RESOLVE | CLASS - 1 | B 254 FOUND PEERLESS PSC-06 GAS FIRED BOILER SER# 5117448-2015 NOT REGISTERED, REGISTER THE BOILER AND SUBMIT A CERTI... | $625 | $0 | Feb 8, 2022 |
| Jan 20, 2018 | 38260742R | RESOLVE | CLASS - 1 | (C/U 5-A-10);32-H-10;68-B-7;71-Q-3;48-Y-10.5-A-10(CEASE USE)DOOR RESTRICTOR TAMPERED W/OR RENDERED INOPERATIVE THIS I... | $1,000 | $0 | Mar 6, 2018 |
| Aug 29, 2009 | 38204345R | ACTIVE | CLASS - 2 | 10H11.99M7.77Q7.10H11 REPLACE WORN CAR DOOR GIBS 99M7 PROVIDE 1 YR PRESSURE TEST TAG 24I10 REPAIR LOBBY AND CAR P.I.'... | $250 | $0 | Nov 10, 2009 |
| Aug 29, 2009 | 38204344P | RESOLVE | CLASS - 2 | 10H11.99M7.77Q7.10H11 REPLACE WORN CAR DOOR GIBS 99M7 PROVIDE 1 YR PRESSURE TEST TAG 12Q7 PROVIDE COVER FOR CAR LIGHT... | $250 | $0 | Nov 10, 2009 |
| Mar 24, 2000 | 38095263N | RESOLVE | Non-Hazardous | 07X11. 07-X-11. ELECTRIC EYE. | $2,500 | $0 | May 9, 2000 |
| Mar 24, 2000 | 38095262L | RESOLVE | Non-Hazardous | 57Y14,57O02,35Y14,35O02. 35-R- NO STORAGE IN M.R. | $2,500 | $0 | May 9, 2000 |
| Sep 24, 1998 | 38079691J | ACTIVE | Non-Hazardous | 35O,43Y,57O,74U. REMOVE NON ELEVATOR MATERAL FROM MR AND CLEAN EXCESS OIL FROM FLOOR. | $180 | $0 | Apr 10, 2002 |
| Sep 24, 1998 | 38079690H | RESOLVE | Non-Hazardous | 35O,43Y,57O,74U. REMOVE NON ELEVATOR MATERAL FROM MR AND CLEAN EXCESS OIL, CHANGE WORN SEALS IN PUMP AND PISTON UNITS... | $180 | $0 | Apr 10, 2002 |
| Oct 18, 1997 | 38064398Z | RESOLVE | Non-Hazardous | 35O2,31Q7. PUMP ROOM USED FOR STORAGE. REMOVE STORAGE. THROUGHOUT. | $1,000 | $0 | Apr 28, 1998 |
| Oct 18, 1997 | 38064397R | RESOLVE | Hazardous | 01L, 02L, 01 & 02-ST. LOW & ALARM NOT WORKING. | $1,000 | $0 | Feb 17, 1998 |
| Jan 18, 1991 | 38003694Y | RESOLVE | Non-Hazardous | 7L11, 22I11, 73X#. 73 RESTORE TO SERVICE FOR THE PURPOSE OF INSPECTION. | $75 | $0 | Jun 4, 1991 |