ECB violations
118-02 Ocean Promenade, Queens • Block 16228 • Lot 0041
19 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 26, 2025 | 39152124H | ACTIVE | CLASS - 1 | CLASS 1. DOOR ZONE RESTRICTOR IS NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWE... | $6,250 | $6,250 | Sep 2, 2025 |
| Jan 5, 2024 | 39524554M | RESOLVE | CLASS - 2 | SUSPENDED SCAFFOLD OPERATIONS IN PROGRESS EXP1 GRINDING,CHIPPING MASON WALL,NO OVERHEAD PROTECTION IN PLACE AT PUBLIC... | $2,400 | $0 | Mar 12, 2024 |
| Jan 5, 2024 | 39524555Y | RESOLVE | CLASS - 2 | BC3314.4.1.5REVIEWED DEPT.RECORDS NO NOTIFICATION PROVIDED INSTALLATION OUTRIGG.EQUIPMENT IN USE AT TIME OF INSPECTIO... | $2,500 | $0 | Mar 12, 2024 |
| Sep 14, 2020 | 35537318H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC... | $1,250 | $1,250 | Mar 2, 2021 |
| Aug 23, 2019 | 39008338R | RESOLVE | CLASS - 2 | INSTALLING NEW ELECTRICAL CABLES IN KITCHEN AND LIVING ROOM CEILING FOR NEW LIGHT FIXTURES., OBTAIN ALL PERMITS | $0 | $0 | Oct 8, 2019 |
| Feb 1, 2019 | 38267500X | ACTIVE | CLASS - 2 | 32.H.11,08.L.10,24.L.11,59.M.07,80.M.07=(32-H-11)REPLACE RIGHT SIDE GUIDE SHOES(08-L-10)NEED TO BE FIXED HANDRAILS IN... | $3,125 | $0 | Apr 9, 2019 |
| Sep 9, 2011 | 34924990J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES NOTED NORTH & EAST FACADES W/ CRACKS PRESENT AT BRICK AT VARIOUS LOCAT... | $1,000 | $0 | Mar 20, 2012 |
| Jul 23, 2008 | 38188531N | RESOLVE | CLASS - 3 | 70O02,77M07,98BB05,99BB05. 77M07 PROVIDE TOE GUARD. | $500 | $0 | Oct 20, 2009 |
| May 7, 2007 | 38166195X | RESOLVE | Non-Hazardous | 84I10/39I10/40L11/5H10/10M7/83O2/.84-I-10-REPAIR BRICKWORK & POINTING TOP OF SHAFTWAY.39-I-10-REPAIR MACHINE ROOM BRI... | $350 | $0 | Mar 31, 2009 |
| May 7, 2007 | 34539747Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL. ROOF LEVEL-ELEVATOR AND STAIRSBULKHEADS AND CHIMNEY-CRACKS BETW BRICKS, MISSI... | $0 | $0 | Nov 13, 2007 |
| Dec 2, 2005 | 34503742P | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. NOTED: 1) AT NORTH WEST CORNER FIRE ESCAPE FROM SECOND FLOOR TO FIRST FLOOR. RUSTED CRUMBLE AND ... | $800 | $0 | Jan 17, 2006 |
| Sep 1, 2005 | 34489750R | RESOLVE | Non-Hazardous | EXIT PASSAGE OR CORRIDOR REQUIRED WIDTH DECRESED BY OBSTRUCTION NOTED TENANT OF APT 5G INSTALLED AC UNIT IN THE WINDO... | $180 | $0 | Oct 18, 2005 |
| Dec 12, 2002 | 34375857L | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT; WORK NOTED: GUTTERED APT 6F AND APT 6C TO MAKE ONE APT NO WORK GOING ON AT TIME OF INSPECTION. R... | $0 | $0 | Jan 28, 2003 |
| Jan 3, 2001 | 38110186L | RESOLVE | Non-Hazardous | 40B07,4O PROVIDE UP OVE SPEED TRIPPING SWITCH AND CERTIFY TO PROPER CALIBRATION AS PER ANSI A:17.1 SECTIONS 206,4A AN... | $0 | $0 | Feb 20, 2001 |
| Mar 24, 2000 | 38095261J | RESOLVE | Non-Hazardous | 75U05,40B07. 40B07-PROVIDE CALIBRATED UP OVERSPEED TRIPPING SWITCH AS PER ANSI A17.1 SECTION 206.4A AND 206.4B (3) | $350 | $0 | Sep 13, 2000 |
| Sep 9, 1998 | 38079501J | RESOLVE | Non-Hazardous | 40B,35I,09M,36T,74M, 40- PROVIDE UP OVERHEAD TRIPPING SWITCH AND CERTIFY TO PROPER CALIBRATION AS PER ANSI A:17:1 SEC... | $2,500 | $0 | Oct 27, 1998 |
| Jan 9, 1998 | 38064396P | RESOLVE | Non-Hazardous | 14M,31Q,09B,57O,74D, 31 THROUGHTOUT 09 BEND DOWN FIRE ON CAR DOOR 74 LOOSE GREENFEILD AT BOTTOM LIMITS | $2,500 | $0 | Mar 3, 1998 |
| Jan 7, 1994 | 38039726Y | RESOLVE | Non-Hazardous | 75#, 75#- PERFORM 5 YEAR TEST. PROPERLY TAG DEVICE AND FILE ELEV 3 FORM | $0 | $0 | Feb 22, 1994 |
| Jan 18, 1991 | 38003695X | RESOLVE | Non-Hazardous | 14I,22D,74L, (74) REPAIR OUTRIGGER ANGLE ON TOP OF CAR AND SECURE VENTILATION LOUVRE. | $1,000 | $0 | May 7, 1991 |