ECB violations
130 Beach 120 Street, Queens • Block 16229 • Lot 0048
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 26, 2026 | 35726444L | ACTIVE | CLASS - 2 | 28-103.8. FAILURE TO MAINTAIN EMBEDED SAFETY STRAPS INSTALLATION INSPECTION LOG BOOKS ON SITE. AS NOTED: AT TIME OF I... | $1,250 | $1,250 | Sep 1, 2026 |
| Mar 25, 2026 | 39552180P | RESOLVE | CLASS - 2 | ACTIVE 8STORY NB. OBSERVED SUPPORTED SCAFFOLD AT EXPOSURES 1,2 AND 4 W/ INADEQUATE AND LOOSE NETTING. SCAFFOLD CONDIT... | $2,500 | $0 | Jun 2, 2026 |
| Mar 25, 2026 | 39552182Z | RESOLVE | CLASS - 2 | ACTIVE 8STORY NB. OBSERVED DUMPSTER OCCUPYING STREET AT EXPO1. UPON RESEARCH ON DOTRECORDS, AND REQUEST, NO ACTIVE DO... | $625 | $625 | Jun 2, 2026 |
| Mar 25, 2026 | 39552181R | RESOLVE | CLASS - 2 | ACTIVE 8STORY NB, OBSERVED CONSTRUCTION FENCE AT EXPOSURES 3 & 4 UNMAINTAINED AND IN DISREPAIR. AT EXPO4 FENCE POSTS ... | $1,000 | $1,000 | Jun 2, 2026 |
| Mar 25, 2026 | 39552183K | RESOLVE | CLASS - 2 | ACTIVE 8STORY NB. EXCESSIVE AMOUNT OF COMBUSTIBLE MATERIAL &DEBRIS STORED HAZARDLY ON EVERY FLOOR THRUOUT SITE FROM C... | $0 | $0 | Jun 2, 2026 |
| Jun 5, 2025 | 39541106N | ACTIVE | CLASS - 2 | PROPOSED 8 STORY NEW BUILDING AT SUPERSTRUCTURE PHASE WITH ACTIVE CONSTRUCTION OPERATIONS, MISSING ROOF PROTECTION FO... | $6,250 | $6,250 | Jan 28, 2027 |
| Apr 22, 2025 | 39145613N | RESOLVE | CLASS - 2 | NO EN DRAWING APPROVED FROM DOB PROVIDED ON THE JOB SITE AT THE TIME OF INSPECTION., MAINTAIN/DISPLAY REQUIRED DOCUME... | $1,280 | $0 | Jul 1, 2025 |
| Apr 1, 2025 | 39538604Z | RESOLVE | CLASS - 1 | DURING INSPECTION I REQUESTED TO SEE THE SITE SAFETY PLAN, SIDEWALK SHED AND SUPPORTED SCAFFOLD DRAWINGS/DOCUMENTS AN... | $2,500 | $2,500 | Dec 1, 2025 |
| Apr 1, 2025 | 39538606M | RESOLVE | CLASS - 2 | DURING INSPECTION OF A 8 STORY BUILDING, I OBSERVED THAT PART OF THE FENCE THAT WAS AT EXPOSURE #1 AND #2 IN FRONT OF... | $1,000 | $1,000 | Jun 15, 2026 |
| Apr 1, 2025 | 39538603R | RESOLVE | CLASS - 1 | DURING INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED THAT THERE WAS CONSTRUCTION DEBRIS THROUGHOUT THE 1ST FL... | $2,500 | $2,500 | Jun 15, 2026 |
| Apr 1, 2025 | 39538605K | RESOLVE | CLASS - 1 | BC 3314.1 SCOPE SCAFFOLD: DURING INSPECTION OF AN 8 STORY BUILDING WITH SUPPORTED SCAFFOLD IN PLACE AT ALL EXPOSURES,... | $5,000 | $5,000 | Dec 1, 2025 |
| Jan 3, 2025 | 35689163P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSI... | $6,250 | $6,250 | Oct 27, 2026 |
| Dec 11, 2023 | 39101092M | RESOLVE | CLASS - 1 | OBSERVED NO EGRESS/INGRESS FROM EXCAVATED AREA, NO GUARD RAILING PROVIDED AROUND EXCAVATED AREA AND SHAFT PIT WHERE R... | $6,250 | $6,250 | Feb 20, 2024 |
| Aug 27, 2014 | 35026147H | RESOLVE | CLASS - 2 | WORK W.O A PERMIT.NOTED @ FRONT ON ROOF.INSTALLED & ERECTED METAL CHIMNEY APPROX 8'HIGH FROM TOP OF ROOF.REM:OBTAIN P... | $400 | $0 | Oct 28, 2014 |
| Dec 21, 1992 | 34080915M | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT: WORK NOTED: REMOVED INTERIOR PARTITIONS AT SECOND LEVEL. ENCLOSED WINDOW OPENING AT BATHRM ON ... | $350 | $0 | Feb 2, 1993 |