Maintenance code violations
1051 Victory Boulevard, Staten Island • Block 00244 • Lot 0064
61 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Apr 3, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD-DOORS OFF HINGES AT BASE CABINETS IN THE KITCHEN ... | 1FL | May 8, 2013 |
| Apr 3, 2013 | C | VIOLATION CLOSED | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK, STONE AND CEMENT ( APPROX... | — | Apr 9, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES '' SHOWER-HEAD '' IN THE BATHROOM LOCAT... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES '' SHOWER-HEAD '' IN THE BATHROOM LOCATE... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS AND CEI... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL AT B... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD AND VINYL TILES FLOOR IN TH... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING COVER AT ELECTRICAL LIGHT-SWITCH EAST WALL IN THE 1st ROOM FROM N... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE COVER AT ELECTRICAL OUTLET LOWER WEST WALL IN THE 2nd... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT STAIRS IN THE PRIVATE HALLWAY LOCATED AT APT 1FL, 1st STORY | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... PRESENT AT CEILING ( APPROX-2... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WASHBASIN TO EAST WALL IN THE BATHROOM LOCATED AT APT 1FL UPPER LEVE... | 1FL | May 7, 2013 |
| Apr 2, 2013 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN... | 1FL | Jul 6, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE UNDER SINK IN THE KITCHEN LOCATED AT APT 1... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN TH... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE COVER AT ELECTRICAL LIGHT-SWITCH EAST WALL IN THE 2nd... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE NORTH AND WES... | 1FL | May 7, 2013 |
| Apr 2, 2013 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR WALLS AND CEILING... | 1FL | May 7, 2013 |
| Nov 8, 2012 | B | NOV SENT OUT | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 1 | Dec 13, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT SWITCH AT SOUTH WALL IN THE BATHROOM LOCATED AT ... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BOTTOM CEMENT STEP AT FRONT AT S... | — | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE KITCHEN LOCATED AT APT HOUSE, 1st STORY | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS AND CEI... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING AND EAST ... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | A | NOV SENT OUT | § 27-2005 ADMIN. CODE: REFIT WINDOW LOWER SASH AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT HOUSE UPPER LEV... | HOUSE | Jan 21, 2013 |
| Oct 18, 2012 | C | NOV SENT OUT | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT... | HOUSE | Nov 8, 2012 |
| Oct 18, 2012 | A | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM ... | HOUSE | Jan 21, 2013 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL CEILINGS AND ... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE OVEN AT STOVE IN THE KITCHEN LOCATED AT AP... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINETS WEST WALL IN THE K... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT HOUSE U... | HOUSE | Nov 22, 2012 |
| Oct 18, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE BAT... | HOUSE | Nov 22, 2012 |
| Sep 7, 2012 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 1 | Oct 12, 2012 |
| Sep 7, 2012 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN... | 1 | Dec 11, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERMAIC TILES AT NORTH WALL IN T... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE 2n... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR NORTH WALL IN THE... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF CONCEALED WATER LEAK OVER CEILING IN THE KITCHEN ... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN IN THE BATHROOM LOCATED AT APT HOUSE UPPE... | HOUSE | Apr 19, 2012 |
| Mar 15, 2012 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT STEP AT STOOP | — | Apr 19, 2012 |
| Jan 5, 2012 | B | NOV SENT OUT | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... | 1 | Feb 9, 2012 |
| Dec 8, 2011 | B | NOV SENT OUT | § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD AND VINYL TILES FLOOR IN TH... | PH | Jan 12, 2012 |
| Dec 8, 2011 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASHBASIN IN THE BATHROOM LOCATED AT APT PH UPPER... | PH | Jan 12, 2012 |
| Dec 8, 2011 | A | NOV SENT OUT | § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN... | PH | Mar 12, 2012 |
| Dec 8, 2011 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE LEAKING AT SINK IN THE KITCHEN LOCATED AT... | PH | Jan 12, 2012 |
| Dec 8, 2011 | B | NOV SENT OUT | § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE LEAKING AT WASHBASIN IN THE BATHROOM LOCAT... | PH | Jan 12, 2012 |