ECB violations
91 Broad Street, Staten Island • Block 00526 • Lot 0014
10 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 28, 2021 | 35547712P | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCE OR WIRING IN USE ON 8/28/2021... | $2,000 | -$2,000 | Nov 3, 2021 |
| Jun 19, 2017 | 35242032Y | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO & DEPARTMENT OF BUILDINGS RECORDS.PARTITIONS ERECTED CREATING ILLEGAL USE ... | $0 | $0 | Dec 13, 2017 |
| Dec 30, 2005 | 34504541N | RESOLVE | Hazardous | SIDEWALK SHED DOES NOT MEET BLDG. CODE SPECIFICATIONS (A) NO LIGHT IS WAS VERY DARK & SIDEWALK SHED DARK. REMEDY: CON... | $5,000 | $0 | Apr 19, 2006 |
| Aug 12, 2005 | 34488887N | RESOLVE | Hazardous | SIDEWALK SHED NOT ADEQUATELY MAINTAINED. SIDEWALK SHED DECKING IS SEVERELY DETERIORATED DUE TO WEATHER WITH HOLES, IT... | $5,000 | $0 | Oct 5, 2005 |
| Aug 12, 2005 | 34488888P | RESOLVE | Hazardous | FAILURE TO MAINTAIN: DEFECT NOTED: STRUCTURE IS MISSING ROOF WITH INTERIOR FLOOR BEAMS COLLAPSED AT 3RD, 2ND, & 1ST F... | $2,500 | $0 | Oct 5, 2005 |
| Aug 12, 2005 | 34488886L | RESOLVE | Hazardous | SIDEWALK SHED DOES NOT MEET BLDG CODE SPECIFICATIONS: A)NO LIGHT: NO CONDULT, NO LIGHT BULBS, NO WIRING, NO LIGHT FIX... | $5,000 | $0 | Oct 5, 2005 |
| Jun 2, 2005 | 34482603P | RESOLVE | Hazardous | SIDEWALK SHED NOT ADEQUATELY MAINTAINED: PLYWOOD DECKING FOR SIDEWALK SHED IS DETERIORATED CREATING DEFICIENT AREAS I... | $5,000 | $0 | Aug 3, 2005 |
| Jun 2, 2005 | 34482601L | RESOLVE | Hazardous | FAILURE TO MAINTAIN: DEFECT NOTED: ROOF COMPLETELY MISSING, ALSO 3RD FLOOR, 2ND FLOOR COMPLETELY MISSING, BUILDING OP... | $2,500 | $0 | Aug 3, 2005 |
| Jun 2, 2005 | 34482602N | RESOLVE | Hazardous | SIDEWALK SHED DOES NOT MEET BUILDING CODE SPECIFICATIONS: A) NO LIGHT-NO FIXTURES X ELECTRICAL CONDUIT (WIRING) INSTA... | $5,000 | $0 | Aug 3, 2005 |
| Aug 6, 2001 | 34285980H | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. NOTED: 3 STORY BRIOR BUILDING ROOF HAS CAVED IN TAKING WITH IT MORE THAN HALF OF THE SECOND FLOO... | $800 | $0 | Dec 20, 2001 |