54 Irving Place, Staten Island • Block 00641 • Lot 0023

15 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
May 4, 2021 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT 1ST WINDOW FROM EAST A... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1FL, 1st STORY, ... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE SOUTH WALL IN... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING, WEST , S... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE WEST WALL AND... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1FL, 1st ... 1FL Jun 8, 2021
May 4, 2021 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM ... 1FL Jun 8, 2021
I VIOLATION CLOSED §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
May 3, 2021 C VIOLATION CLOSED § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1FL, 1st ST... 1FL Apr 30, 2021
Nov 12, 2020 B VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL UNDER SINK (APPROX ... 1FL Dec 17, 2020
Jul 14, 2020 B VIOLATION CLOSED § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1FL, 1st STORY 1FL Aug 18, 2020
Jul 14, 2020 A VIOLATION CLOSED § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD WINDOW STOOL AT SOUTH WALL ... 1FL Oct 17, 2020
Jul 14, 2020 A VIOLATION CLOSED § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR CEILING IN THE PR... 1FL Oct 17, 2020
Jul 14, 2020 B VIOLATION CLOSED § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER WINDOW SASH AT SOUTH WALL IN... 1FL Aug 18, 2020
Jul 14, 2020 A VIOLATION CLOSED § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WEST WALL UNDER SINK (APPROX ... 1FL Oct 17, 2020