| Apr 12, 2022 | 35646420R | RESOLVE | CLASS - 1 | BC 3314.8 GUARDRAIL SYSTEM AND DEBRIS NETTING.AT THE TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SUPPORTED SCAFFO... | $2,500 | $0 | Jun 1, 2022 |
| Apr 12, 2022 | 35646421Z | RESOLVE | CLASS - 1 | BC 3314.5 SCAFFOLD PLATFORM CONSTRUCTION AT THE TIME OF INSPECTION OF 6 STORY BUILDING ACTIVE JOBSITE OBSERVED EXTERI... | $2,500 | $0 | Jun 1, 2022 |
| Feb 19, 2022 | 35641440L | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE.AT TIME OF INSPECTION OF 6 STORY NB,ACTIVE JOB SITE,... | $2,500 | $0 | Apr 6, 2022 |
| Feb 19, 2022 | 35641439Y | RESOLVE | CLASS - 2 | BC3314.4 SUPPORTED PIPE SCAFFOLD NOT INSTALLED,MAINTAINED AS PER CODE.AT TIME OF INSPECTION OF 6 STORY NB,ACTIVE JOB ... | $0 | $0 | Apr 6, 2022 |
| Jan 10, 2022 | 35565714H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39051353Z ISSUED ON 11/17/21 AND TO FIL... | $0 | $0 | Mar 2, 2022 |
| Dec 20, 2021 | 35505238L | RESOLVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF COMPLIANCE W/WORKERS COMP,LAW&DISABILITY BENEFITS LAW.ATO MY INSP OF 6STYNB ACTIVE SITE I... | $5,000 | $0 | Apr 13, 2022 |
| Nov 18, 2021 | 35505612M | RESOLVE | CLASS - 1 | PRE-SHIFT SAFETY MEETINGS.AT THE TIME OF INSPECTION IN RESPONSE TO AN INCIDENT WHERE IT WAS REPORTED BY FDNY THAT FIR... | $0 | $0 | Jan 5, 2022 |
| Nov 18, 2021 | 35505610Z | RESOLVE | CLASS - 1 | CONSTRUCTION SUPERINTENDENT FAILED TO IMMEDIATELY NOTIFY THE DEPARTMENT OF AN ACCIDENT.AT THE TIME OF INSPECTION IN R... | $0 | $0 | Jan 5, 2022 |
| Nov 18, 2021 | 35505609L | RESOLVE | CLASS - 1 | FAILURE TO IMMEDIATELY NOTIFY THE DEPARTMENT OF AN ACCIDENT.AT THE TIME OF INSPECTION IN RESPONSE TO AN ACCIDENT WHER... | $0 | $0 | Jan 5, 2022 |
| Nov 17, 2021 | 39051353Z | RESOLVE | CLASS - 1 | ACTIVE ONGOING CONSTRUCTION SITE AT 2ND FLOOR WELDING WORK CAUSE FIRE ON INSULATED WALL APPROX. 10' LONG AND 8' HEIGH... | $0 | $0 | Jan 5, 2022 |
| Oct 21, 2021 | 35591264Z | RESOLVE | CLASS - 1 | BC3309.10 PROTECTION OF ROOFS ATOI OBSERVED THAT ROOF PROTECTION WAS MISSING@COPING STONES@EXP4.PROTECTION SHALL EXTE... | $625 | $0 | Mar 9, 2022 |
| Oct 5, 2021 | 35589796R | RESOLVE | CLASS - 2 | BC33141-SUPPORTED SCAFFOLD DOES NOT MEET CODE SPECIFICATION.NOTE:AT THE TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUC... | $0 | $0 | Dec 1, 2021 |
| Oct 5, 2021 | 35589795P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTES AT THE TIME OF INSPECTION I... | $0 | $0 | Dec 1, 2021 |
| Mar 28, 2011 | 34856864R | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. BASED ON PHYSICAL OBSERVATION OF WORK DONE IN BASEMENT OBSERVED SUMP PUMP PLACED IN A BUCKET & 2" ... | $800 | $0 | Jun 8, 2011 |
| Jul 15, 1988 | 32000654H | RESOLVE | Hazardous | — | $110 | $0 | Sep 8, 1988 |