ECB violations

East 161 Street, Bronx • Block 02460 • Lot 0001

143 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 11, 2026 39557787Y ACTIVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED 11-STORY BUILDING WITH SIDEWALK SHED AT EXPOSURES 1, 2, AND 4. NO WORK WAS OBSERVED. ... $2,400 $2,400 Oct 16, 2026
Jun 2, 2026 39554932H ACTIVE CLASS - 2 AT THE TIME OF INSPECTION OF A 10 STORY BUILDING SIDEWALK SHED WITH VALID PERMIT OBSERVED. NO ELECTRICAL PERMIT FOR T... $1,280 $1,280 Aug 7, 2026
Apr 20, 2026 37036426M ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 6, 7C, 8C, AND 9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBE... $6,280 $6,280 Jul 17, 2026
Feb 26, 2026 35726412R ACTIVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE-EXPIRED PERMIT. NOTE: AT TIME OF INSPECTION, I OBSERVED ELEC... $1,250 $1,250 Oct 2, 2026
Feb 26, 2026 35726411P ACTIVE CLASS - 2 TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE EXPIRED PERMIT(SHED). NOTE: AT TIME OF INSPECTION, I OBSERVED SIDEWALK S... $1,250 $1,250 Oct 23, 2026
Jan 7, 2026 39548867J ACTIVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED WITH PERMIT EXPIRED 08/25/2023 REMAINING IN PLACE. CONTRARY TO BC 105.8... $1,250 $0 Mar 20, 2026
Aug 21, 2025 39543900J RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK SHED IN PLACE WITHOUT INFORMATION PANEL CAUSING HAZARDOUS CONDITIONS.PROVIDE ... $1,250 $0 Feb 27, 2026
Aug 21, 2024 39531637N RESOLVE CLASS - 2 AT TIME OF INSPECTION OF 10 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT 220161278 EXPIRED 8-... $0 $0 Nov 1, 2024
Feb 21, 2024 39106708Y ACTIVE CLASS - 2 EXCESSIVE STEAM COMING OUT OF CONDESATION TANK/REAR BOILER DOORS MISSING DAWGS/CHIMNEY CAP BROKEN/CORRECT ALL VIOLATI... $625 $625 Sep 10, 2024
Feb 21, 2024 39106518N ACTIVE CLASS - 1 FOUND ROCKMILL MP300SL OIL FIRED STEAM BOILER.CEASE USE DUE TO HAZARDOUS CONDITION: BOILER FLUE PIPE BREACHING COMPLE... $1,250 $1,250 Sep 10, 2024
Feb 21, 2024 39106511K ACTIVE CLASS - 1 FOUND ROCKMILL MP300SL OIL FIRE STEAM BOILER.CEASE USE DUE HAZARDOUS CONDITION; BOILER FLUE PIPE BREACHING WAS COMPLE... $1,250 $1,250 Sep 10, 2024
Jan 16, 2024 37026574P ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 6,7B,8B,AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED I... $1,250 $1,250 May 3, 2024
May 16, 2023 38274833J ACTIVE CLASS - 1 97X17 ENTIRE DEVICE INOPERATIVE.UPON INSPECTION THE DEVICE IS FOUND TOBE OUT OF SERVICE CREATING A HAZARDOUS CONDITIO... $12,500 $0 Jul 21, 2023
Apr 28, 2023 39516000K RESOLVE CLASS - 1 FAILURE TO PROVIDED ADEQUATE LIFELINES WHILE WORKING ON A SUSPENDED SCAFFOLD. AT TIME OF INSPECTION, OBSERVED AN ACTI... $2,500 $0 Jan 12, 2024
Apr 28, 2023 39515979N RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED ACTIVE SITE, TWO SUSPENDED SCAFFOLD INSTALLED AND ONE BEING INSTALLED. SUSPENDED SCAFF... $0 $0 Jul 7, 2023
Apr 28, 2023 39515997R RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED ONE ACTIVE SUSPENDED SCAFFOLD ONE READY TO USE AND ONE MORE IN PROCESS OF BEING INSTAL... $0 $0 Jul 7, 2023
Apr 28, 2023 39516004H RESOLVE CLASS - 1 AT TIME OF INSPECTION, OBSERVED AN ACTIVE SUSPENDED SCAFFOLD AT EXPOSURE 3. PARAPET HAS BEING DEMOLISH CREATING A FAL... $2,500 $0 Jul 7, 2023
Apr 14, 2023 39083801J ACTIVE CLASS - 2 RESTORE ELEVATOR TO SERVICE, ELEVATOR STUCK ON 2ND FLOOR $3,125 $0 Jun 30, 2023
Feb 20, 2023 39079953R ACTIVE CLASS - 1 RESPONDING TO A 311 ELEVATOR, UPON INSPECTION ON THE NORTH SIDE OF BUILDING ELEVATOR #3 FOUND TO BE OUT -OF -SERVICE ... $6,250 $0 May 5, 2023
Nov 23, 2022 39074391L ACTIVE CLASS - 2 ROCKMILL MP300SL BOILER'S DRAFT HOOD STARTING TO SHOW SIGNS OF CORROSION; CORRECT VIOLATING CONDITION & SUBMIT A CERT... $3,125 $0 Feb 3, 2023
Aug 3, 2022 39504555X RESOLVE CLASS - 2 NOTE: OBSERVED WORKERS DOING BRICK & COOPING WORK ON ROOF OF 1STY ROUND SHAPED EXTENDED PORTION OF THE BUILDING(10STY... $2,400 $0 Dec 13, 2022
May 23, 2022 39062658N ACTIVE CLASS - 1 CEASE USE VIOLATION ISSUED, TILLER ROPE DAMAGE REPAIR THEN CONTACT NYCDOB FOR RESTORE TO SERVICE RE-INSPECTION. $1,250 $0 Jun 28, 2024
Apr 27, 2022 39061111P ACTIVE CLASS - 2 FOUND BOILER NOT OPERABLE, EXPOSED WIRING, DIRTY GLASS GAUGE, DIRTY STEAM GAUGE, ALL BOILER ROOM DOORS ARE TO BE SELF... $312 $0 Sep 30, 2022
Mar 22, 2022 39058583X ACTIVE CLASS - 1 CLASS 1 VIOLATION ISSUED, NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3. 10.12 OF APPENDIX K3... $12,500 $0 May 6, 2022
Mar 22, 2022 39058584H ACTIVE CLASS - 1 CLASS 1 VIOLATION ISSUED, NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 ... $12,500 $0 May 6, 2022
Mar 21, 2022 39058470J ACTIVE CLASS - 1 CEASE USE, VIOLATION ISSUED, TILLER ROPE DAMAGED AND FAIL SAFETY TEST, REMEDY, REPAIR AND DO PULL THROUGH TEST ON DEV... $6,250 $0 May 6, 2022
Jan 26, 2022 39054876L ACTIVE CLASS - 1 CARBON MONOXIDE DETECTED IN BLR ROOM-GAS FLEX USED TO CONNECT PIPING FROM COMPRESSOR TO BURNER-OIL STORED AT BURNER-F... $6,250 $0 Mar 18, 2022
Dec 10, 2021 39052666Y ACTIVE CLASS - 2 CLASS 2 VIOLATION ISSUED ,/ IN CAR MIRROR MISSING. REMEDY,PROVIDE,/ BRAKE TAG EXPIRED. REMEDY. PROVIDE UP TO DATE TAG... $3,125 $0 Mar 18, 2022
Sep 3, 2021 39046967R ACTIVE CLASS - 1 CLASS 2 VIOLATION ISSUED,/ GRAND FLOOR INDICATOR BOARD NOT WORKING, REPAIR ,/ IN CAR MIRROR MISSING, PROVIDE,/ BRAKE ... $6,250 $0 May 6, 2022
Feb 10, 2021 39036079J ACTIVE CLASS - 2 FOUND FRONT BOILER DOORS NEED TO BE RESEALED, EXCESSIVE SOOT ALL OVER CONTROLS AND ON TOP OF BOILER, WATER LEAKING AT... $3,125 $0 Dec 10, 2021
Nov 20, 2020 39032282R ACTIVE CLASS - 2 BOILER #2 -FOUND BURNER NEEDS SERVICING (BAD VIBRATION), BOILER DOORS FRONT AND REAR NEED TO BE RESEALED, DIRTY GLASS... $3,125 $0 Jan 15, 2021
Nov 20, 2020 39032281P ACTIVE CLASS - 2 ON BOILER #1- FOUND TO HAVE EXPOSED WIRING, BOILER DOORS FRONT AND REAR DOORS NEED TO BE RESEALED, LATCHES MISSING ON... $3,125 $0 Jan 15, 2021
Jun 3, 2020 37019181Z ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABEL AMENDDED CYCLE 7B REPORT INDICATING CORRECTION FO UNSAFE CONDITIONS DESCRIBED IN INITIAL F... $1,250 $0 Jul 9, 2021
Apr 14, 2020 39021096J ACTIVE CLASS - 1 CLASS 1= NO DOOR LOCK MONITORING, INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2O14 NYCB... $6,250 $0 Sep 11, 2020
Sep 7, 2019 38271532M RESOLVE CLASS - 2 (80M7,26D5,25M7,40P16,2X10)80M#-PROVIDE SIGNAGE ON DEVICE.26D#SECURE TO CODE.25M#PROVIDE SINAGE ON ALL FLOORS(IN CASE... $310 $0 Nov 1, 2019
Jul 8, 2019 35437434R RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION # BC3307.6.5.3, FAILURE TO MAINTAIN SIDEWALK SHED. NOTE: AT TH... $2,400 $0 Aug 30, 2019
May 22, 2019 35422568K ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED:AT TIME OF INSPECTION I OBSERVED DEFECTIVE WALL IS (1)MI... $625 $0 Jul 19, 2019
May 13, 2019 35418344J ACTIVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS AS PER 2207.648.1 NOTE AT TIME OF INSPECTION I OBSERVED SIDEW... $1,250 $0 Jul 5, 2019
Mar 13, 2019 35248701J ACTIVE CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS:(1)MISSING,CRACKED AND BULGING STONE WORK AT VARIOUS LOCATIONS,... $12,500 $0 May 3, 2019
Oct 15, 2018 37013340J ACTIVE CLASS - 2 FAILURE TO SUBMIT Q REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $6,250 $0 Mar 15, 2019
Sep 11, 2018 35351858N RESOLVE CLASS - 1 ILLEGAL SIGNS. NOTE AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE WITH ILLEGAL ADVERTISEMENTS ON PARAPET. R... $0 $0 Nov 2, 2018
Aug 28, 2018 35351712K RESOLVE CLASS - 2 3307.6.5.8-FAILURE TO PERFORM PERIODIC INSPECTION OF SIDEWALK SHED.NOTED:AT TIME OF INSPECTION SEVERAL LIGHTS FOR THE... $0 $0 Oct 19, 2018
Jul 2, 2018 32096331M RESOLVE CLASS - 2 48,50,16,3. AS PER (B254)FAILURE TO MAINTAIN FOUND ROCKMILLS MP3005L RATED @ 10042000 BTUS RUNNING ON OIL TO BE NOT R... $1,562 $0 Nov 9, 2018
Jul 2, 2018 32096332Y RESOLVE CLASS - 2 4,16,48,50. AS PER(B254)FAILURE TO MAINTAIN, FOUND ROCKMILLS MD 300SC #2(BOILER 4691-02)ROOTED @ 10042000 BTUS ON OIL... $1,562 $0 Nov 9, 2018
Jan 3, 2018 32092709R RESOLVE CLASS - 2 50A-H. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN. (50A)FUEL OIL PUMP IN NEED OF REPAIR. (50B)EXPOSED WIRING ... $0 $0 Mar 2, 2018
Nov 7, 2016 37001535L ACTIVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... $4,000 $0 Mar 3, 2017
Feb 1, 2016 38240819H ACTIVE CLASS - 1 05A10, 68M07. (05/A/10) CAB DOOR RESTRICTOR HAS BEEN TAMPERED W/ (REPAIR). (68/M/07) MAINTENANCE LOG HAS NOT BEEN FIL... $1,000 $0 Sep 23, 2016
Feb 1, 2016 38240822Z ACTIVE CLASS - 1 68M07,05A10,40O02,16L10. 05A10-CAR DOOR RESTRICTOR ITS BEEN TAMPERED WITH (REPAIR); 16L10-SC HATCH DOOR NOT CLOSING P... $1,000 $0 Jul 15, 2016
Feb 1, 2016 38240820P ACTIVE CLASS - 1 05A10,68M07. 05A10-CAB DOOR RESTRICTOR ITS BEEN TAMPERED WITH (REPAIR)68M07-MAINTENANCE LOG IS NOT BEEN FILL OUT (PRO... $1,000 $0 Jul 15, 2016
Feb 1, 2016 38240817Y ACTIVE CLASS - 1 05A10,68M07. 05A10-CAB DOOR RESTRICTOR ITS BEEN TAMPERED WITH(REPAIR) 68M07-MAINTENANCE LOG IS NOT BEEN FILL OUT (PRO... $1,000 $0 Jul 15, 2016