Skip to content

ECB violations

East 161 Street, Bronx • Block 02460 • Lot 0001

143 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 27, 2001 34291899L ACTIVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT.PURSUANT TO RULE R.C.N.Y.32-03(B),INDICATING COR... $400 $0 Jul 6, 2001
Mar 9, 2001 34278585M RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y.32-039B),INDICATI... $0 $0 Jun 1, 2001
Jan 12, 2001 34274144Z RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5),INDICA... $0 $0 Jun 1, 2001
Dec 8, 2000 34274020R RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT. PURSUANT TO RULE R.C.N.Y. 32-03B(5), INIDICATIN... $0 $0 Feb 2, 2001
Oct 30, 2000 34248840N ACTIVE Hazardous FAILURE TO FILE AN AMEND ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT.PURSUANT TO RULE R.C.N.Y.32-03B(5)INDICATING CORRE... $1,000 $0 Jan 12, 2001
Sep 18, 2000 34249153X RESOLVE Hazardous FAILURE TO FILE AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT PURSUANT TO RULE R.C.N.Y.32-03B(5),INDICATING CORRE... $0 $0 Jun 1, 2001
Jul 14, 2000 34248430K RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... $0 $0 Oct 27, 2000
Jun 5, 2000 34248793J RESOLVE Hazardous FAILURE TO FILE AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT. PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDICATING CO... $0 $0 Sep 29, 2000
May 20, 2000 38097930R RESOLVE Non-Hazardous 37D06,50H08,54U16,57O02,05J11,34M07,(37)PROPERTY SECURE CONTACT ALL WIRES ON CONTROLLER AND PROVIDE COVERS ON CONTACT... $350 $0 Jun 30, 2000
May 20, 2000 38097931Z RESOLVE Non-Hazardous 57O02,73X11,37D07, (37)SECURE CONTACTS ON CONTROLLER AT TIMER (73)RESTORE ELEVATOR TO SERVICE. $350 $0 Jun 30, 2000
May 20, 2000 38097932K RESOLVE Non-Hazardous 57O02,37M07, (37)REPLACE MISSING COVER ON CONTACT ON CONTROLLER. $300 $0 Jun 30, 2000
May 15, 2000 34248707Y RESOLVE Hazardous FAILURE TO SUBMIT A ROUND TECHNICAL RPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCA... $0 $0 Sep 29, 2000
Apr 27, 2000 34235186P ACTIVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT. PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDICATING... $400 $0 Jun 30, 2000
Mar 13, 2000 34235118N ACTIVE Hazardous FAILURE TO SUBMIT A 4TH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY L... $1,000 $0 Jun 30, 2000
Jan 20, 2000 34234949J RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $1,000 $0 Jun 30, 2000
Dec 30, 1999 38091848K RESOLVE Non-Hazardous 37D,73X,57O. PROPERTY SECURE WIRES ON CONTROLLER AND REPLCE CONTACT ON CONTROLLER. RESTORE ELEVATOR TO SERVICE TO BE ... $0 $0 Jun 30, 2000
Dec 29, 1999 38091846R RESOLVE Non-Hazardous 28H,37D,50O,57O. SECURE TIME RELAY ON CONTROLLER, SECURE WIRES ON MAINMACHINE PROVIDE DUCT PIPING AND COVER. $0 $0 Jun 30, 2000
Dec 14, 1999 34234883X RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRE... $1,000 $0 Jun 30, 2000
Oct 14, 1999 34207274R RESOLVE Hazardous FAILURE TO SUBMIT FOURTH ROUN TECHNICAL REPORT. PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENCES AS REQUIRED BY ... $1,000 $0 Jun 30, 2000
Sep 23, 1999 34223406J ACTIVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... $400 $0 Mar 24, 2000
Sep 23, 1999 34223405H ACTIVE Non-Hazardous FAILURE TO PROVIDE 3"HIGH ALPHABETIC LETTER: 1) FOR ELEVATOR BANK LO- CATED NORTH OF ELEVATOR BANK "A" ON FLOOR 1 TO ... $200 $0 Jan 14, 2000
Jul 8, 1999 38088427P RESOLVE Non-Hazardous 37D6,32D6,35A4,37D6,35D6,57Z2,2B7,1B7,14I10,5B1,74M7,30O2. 37-SECURE CONTACT ON CONTROLLER & REPLACE ALL WIRE PROPERT... $180 $0 Sep 10, 1999
Jul 8, 1999 38087799L RESOLVE Non-Hazardous 28H12,9H12,3B4,35O2,30O2,32D6,37D6,50M7,74M7. 3-PATCH HOLE ON CAB WALLBY PHONE. 30-CLEAN CAR TOP & SHAFTWAY. 33-CLEAN... $180 $0 Sep 10, 1999
Jul 8, 1999 38087800J RESOLVE Non-Hazardous 35D7,73X11,50Y14,74M7,30O2. 35-PROVIDE GUARD RAIL OVER MOTOR RM STEPS.73-RESTORE ELEVATOR TO SERVICE TO BE INSP PROPE... $180 $0 Sep 10, 1999
Jul 8, 1999 38088426N RESOLVE Non-Hazardous 53#7,37D6,50Y14,57Z2,14M7,74M7,30O2. 53-PROVIDE MORE LIGHT IN MOTOR RM. 37-REPLACE BROKEN CONTACT COVER ON CONTROLLER... $180 $0 Sep 10, 1999
Jun 11, 1999 34207164X RESOLVE Non-Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Jun 30, 2000
Mar 1, 1999 34188914P RESOLVE Hazardous FAILURE TO SUBMIT A 4TH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OFEXTERIOR WALLS & APPURTENANCES AS REQUIRED BY L... $10,000 $0 May 14, 1999
Dec 11, 1998 34188750H RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $1,000 $0 Apr 9, 1999
Oct 14, 1998 34188502Z RESOLVE Non-Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $400 $0 Jan 8, 1999
Sep 8, 1998 38079169R RESOLVE Non-Hazardous 46K12, 57O02, 09H10, 50Y11, $180 $0 Oct 23, 1998
Sep 8, 1998 38079170Y RESOLVE Non-Hazardous 50Y11, $180 $0 Oct 23, 1998
Sep 8, 1998 38079167N RESOLVE Non-Hazardous 46K12, 32M07, 57O02, 09H12, 32-INSTALL SPLICE BOX ON MAIN MACHINE. $180 $0 Oct 23, 1998
Sep 8, 1998 38079168P RESOLVE Non-Hazardous 46H11, 09H10, 57O02, $180 $0 Oct 23, 1998
Aug 11, 1998 34176670J RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $2,500 $0 Oct 22, 1999
Jun 29, 1998 34176411P RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Oct 9, 1998
Apr 28, 1998 34165593L RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: CRACKED, DEFECTIVE AND SPALSHING CONCRETE AT REAR UNDER APT 1 ... $0 $0 Jan 8, 1999
Oct 14, 1995 38052238L RESOLVE Non-Hazardous 37#,52B,75#.37-INSTALL CITY NUMBER ON ALL EQUIPMENT IN M R.75-PERFORM 5 YEAR TEST PRPERLY TAG DEVICE AND FILE ELEV 3 ... $100 $0 Apr 12, 1996
Feb 27, 1995 34121047J RESOLVE Non-Hazardous FAILURE TO MAINTAIN. DEFECT NOTED: COOKING VENTILATION FLUE DOES NOTEXCEED ABOVE PARAPET WALL ADJOINING BUILDING 900 ... $0 $0 Jun 9, 1995
Aug 2, 1993 34097261N ACTIVE Non-Hazardous FAILURE TO MAINTAIN DETFECT IS COOKING VENTILATION FLUE DO NOT EXCEED ABOVE PARAPET WALL REMEDY FILE PLANS OBTAIN PERMIT $175 $0 Oct 22, 1993
Aug 12, 1992 34078965H ACTIVE Hazardous FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5)INDICATING CORRECT... $400 $0 Oct 22, 1992
Apr 24, 1991 34050026P ACTIVE Non-Hazardous PA CONTRARY TO APPROVED PLAN DATED JULY 7 1981 PRIMARY EXIT 1 EXIT DOOR & FRAME REMOVED EXIT SIGNATURE REMOVED PASSAG... $400 $0 Sep 20, 1991
Mar 1, 1990 34033894K RESOLVE Hazardous FAIURE TO HAVE APPROVED PA PLAN AVAILABLE FOR INSPECTION. REMEDY: PROVIDE APPROVED PA PLAN FORTHWITH FOR INSPECTION. $0 $0 Apr 13, 1990
Feb 1, 1989 34017361H RESOLVE Non-Hazardous PANIC HARDWARE INOPERATIVE AT NORTHWEST INER EXIT DOOR. EXIT SIGNS MISSING AT NORTHWEST EXIT DOOR AND SOUTHWEST EXIT.... $0 $0 Mar 17, 1989