ECB violations
Chauncey Street, Brooklyn • Block 01691 • Lot 0012
80 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 7, 2008 | 38183248P | RESOLVE | Non-Hazardous | 02X10,14M07,03M07,51B07,41A09,40T07,66Z02.02X-CAR PHONE.03M-TOE GUARD.51B-PROPER ANTI SPINOUTS.41A-REMOVE WOOD FROM C... | $0 | $0 | Jun 2, 2008 |
| Oct 31, 2007 | 38178906L | RESOLVE | Non-Hazardous | 83X10. (83) REPAIR & RESTORE ELEVATOR TO SERVICES SO THAT A FULL INSP CAN BE MADE BY THIS DEPT. | $0 | $0 | Dec 24, 2007 |
| Oct 31, 2007 | 38178907N | RESOLVE | Non-Hazardous | 43H08,55Y13,24I10,66O02.59L10,17H11. (43) REGROOVE TRACTION SHEAVE. (55) SEAL OIL LEAK @ MACHINE. (24) REPAIR IN CAR ... | $0 | $0 | Dec 24, 2007 |
| Oct 31, 2007 | 38178908P | RESOLVE | Non-Hazardous | 12B07,24I10,59L10,66O02,17H11. (12) PROVIDE PROPER LIGHTING IN CAR. (24) REPAIR IN CAR INDICATORS. (59) REPAIR LIGHT ... | $0 | $0 | Dec 24, 2007 |
| Jul 24, 2007 | 38168228M | RESOLVE | Hazardous | CEASE USE. 07N11,07X11,55Y13,55O02,55E10. 07-N-X- DEVICE FOUND OPERATING WITH DOOR REOPENING DEVICE INOPERATIVE AND B... | $250 | $0 | Jul 22, 2010 |
| Oct 18, 2006 | 38161029H | RESOLVE | Non-Hazardous | 83X10: REPAIR & RESTORE ELEVATOR TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT. | $0 | $0 | Dec 4, 2006 |
| Oct 16, 2006 | 38161070J | RESOLVE | Non-Hazardous | 83X10: RESTORE TO FULL SERVICE. | $10,000 | $0 | Dec 4, 2006 |
| May 15, 2006 | 38158675P | RESOLVE | Non-Hazardous | 83X10. 83- RETURN ELEVATOR TO SERVICE SO A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT. | $2,500 | $0 | Jul 3, 2006 |
| Aug 30, 2005 | 38154087K | RESOLVE | Non-Hazardous | 07L10/41R09/55H10. 07-L-10-REPAIR AND REPLACE SAFETY EDGE; 41-R-09-REMOVE WRE JUMPER FROM CONTROLLER; 55-H-10-RUMBLE ... | $2,500 | $0 | Apr 10, 2006 |
| Jun 16, 2005 | 38150219P | RESOLVE | Non-Hazardous | 83X10 (83) REPAIR AND RESTORE ELEVATOR TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT. | $180 | $0 | Jan 23, 2006 |
| Apr 26, 2005 | 38152317H | RESOLVE | Non-Hazardous | 66O02/66B07/66T07/59M07/39O02/85M05/39O09/24M07/03L07 66) CLEAN PIT 66) PROVIDE LIGHTS AND GUARDS IN AT 66) PROVIDE A... | $350 | $0 | Jun 13, 2005 |
| Apr 26, 2005 | 38152314M | RESOLVE | Hazardous | 16D06 16) LOBBY DOOR UNSECURE CAN OPEN WITHOUT ELEVATOR AT FLOOR! CEASE USE HAZARDOUS. | $500 | $0 | Jun 13, 2005 |
| Apr 26, 2005 | 38152315Y | RESOLVE | Non-Hazardous | 15M07/59M07/85M05/66Z02 15) PROVIDE CERTIFICATE FRAME 59) PROVIDE LIGHTS IN MOTOR ROOM 85) PROVIDE 5 YEAR TEST TAG. 6... | $350 | $0 | Jun 13, 2005 |
| Apr 26, 2005 | 38152316X | RESOLVE | Non-Hazardous | 15M07/66O02/16X01/59L07 15) PROVIDE CERTIFICATE FRAME 66) CLEAN PIT 16) ADJUST HALL DOORS FOR PROPER OPERATION 59) PR... | $350 | $0 | Jun 13, 2005 |
| Jul 22, 2004 | 38148138K | RESOLVE | Non-Hazardous | 05L10,09Q03,08V01,66Z09.05L-EXCESSIVE CLEARANCE BETWEEN CAR DOOR AND ENCLOSURE.09Q-INSTALL TOE GUARD.08V-6FL. | $350 | $0 | Dec 8, 2004 |
| Jul 22, 2004 | 38148139M | RESOLVE | Non-Hazardous | 83X10.83X-ELEVATOR OUT OF ORDER. | $350 | $0 | Dec 8, 2004 |
| Jul 22, 2004 | 38148140J | RESOLVE | Non-Hazardous | 03I10,09H10,24I10,12I10,12Q03,05L10.03I-DECORATIVE METAL;24-INSIDE CAR.05L-EXCESSIVE CLEARANCE. | $350 | $0 | Dec 8, 2004 |
| Jul 22, 2004 | 38148137Z | RESOLVE | Non-Hazardous | 09H10,84Q03,07X10,12I10,12Q03,24I10,10M03,09M03,66O02.84Q-INSTALL FAN GUARD.24-INSIDE CAR.10M-INSTALL SECOND GIB.09M-... | $350 | $0 | Dec 8, 2004 |
| May 27, 2004 | 38146071X | RESOLVE | Non-Hazardous | 83X10 83-REPAIR AND RESTORE ELEV TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT | $180 | $0 | Jul 12, 2004 |
| May 27, 2004 | 38146070Y | RESOLVE | Non-Hazardous | 09I10/10H11/12B07/17H11/59B07 (09)REPAIR CAR FLOORING (10)REPLACE CAR DOOR GIBS (12)PROVIDE PROEPR LIGHT IN CAR (17)R... | $350 | $0 | Jul 12, 2004 |
| May 27, 2004 | 38146072H | RESOLVE | Non-Hazardous | 03I10/09I10/12B07/39P16/17H11/10H11 03-REPAIR CAB WALL 03-REPAIR CAR FLORRING 39-PROVIDE ACCESS TO MACHINE ROOM 12-PR... | $350 | $0 | Jul 12, 2004 |
| May 27, 2004 | 38146069R | RESOLVE | Non-Hazardous | 83X10 83-REPAIR AND RESTORE ELEV TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT | $350 | $0 | Jul 12, 2004 |
| May 25, 2004 | 32044837P | RESOLVE | Non-Hazardous | CEASE USE 51/48A/11A/44A 1988 FULTON NATL BD 54747 51 BOILER SEALED DUE TO STEAM LEAK UNDER JACKET | $400 | $0 | Jul 12, 2004 |
| Aug 4, 1998 | 32015997L | RESOLVE | Non-Hazardous | 2 | $400 | $0 | Sep 21, 1998 |
| Dec 2, 1997 | 38066567J | RESOLVE | Non-Hazardous | 40B-PROVIDE UP OVER SPEED TRIPPING SWITCH AND CERTIFYING TO PROPER CALIBRATION AS PER ANSI 17-SECTIONS 206.4A AND 206... | $0 | $0 | Jan 26, 1998 |
| Dec 2, 1997 | 38066566H | RESOLVE | Non-Hazardous | 40B-PROVIDE UP OVER SPEED TRIPPING SWITCH AND CERTIFYING TO PROPER CALIBRATION AS ASSL 17-SECTION 206.4A AND 206.4B (3) | $0 | $0 | Jan 26, 1998 |
| Aug 24, 1993 | 38035247Z | RESOLVE | Non-Hazardous | 08V,09M,13I,14M,16H,21L,37U,50U,54U,57O,75#. 75 PERFORM 5YR. TEST, PROPERLY TAG DEVICE, AND FILE FORM ELV3. | $100 | $0 | Nov 22, 1993 |
| Aug 24, 1993 | 38035249M | RESOLVE | Non-Hazardous | 01L,03#,08V,09H,12L,14M,15L,16H,35O,53M,36I,37U,39#,50U,54L,75#. 03 PROVIDE ADEQUTE VENTILATION IN CAR. 39 INSTALLED ... | $850 | $0 | Oct 4, 1993 |
| Aug 24, 1993 | 38035248K | RESOLVE | Non-Hazardous | 35O,37U,50U,54U,57O,73X. 73 RESTORE ELEVATOR TO SERVICE FOR COMPLETE INSPECTION. 75 PERFORM 5YR. TEST, PROPERLY TAG D... | $100 | $0 | Nov 22, 1993 |
| Aug 24, 1993 | 38035246R | RESOLVE | Non-Hazardous | 01L,02L,03#,05L,07L,08V,09H,12I,14M,16H,21L,37U,39H,46Q,50U,53M,54U,57O,74#,75#. 03 PROVIDE ADEQUATE VENTILATION IN C... | $500 | $0 | Oct 4, 1993 |