ECB violations
10-14 Skillman Street, Brooklyn • Block 01885 • Lot 0026
265 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 12, 2018 | 35310917N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BULIDING IN CODE COMPLIANT MANNER.N FIRE STOPPING PER BC 712.3;27-345 OBSERVED ON ALL THE FLOOR N... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331072N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON FLR 2,3,4,5 TAMPER PROOF FLR CONTROL ELECTRONIC ON ... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310906H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN WALLS AND APPURTENANCES.OBSERVED LOOSE AND MISSING BRICKS AT EXPOSURE # 1 AND 4 OF EX... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310907J | RESOLVE | CLASS - 1 | FAILURE TO MAINTIAN BUILDING WALLS OR APPURTENANCES OBERVED LOOSE AND MISSING BRICKS AT EXPOSURE #1 OF EXTERIOR WALLS... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310911M | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. OBSERVED AT FLOORS 1 TO 5 ERECTED FULL HEIGHT PARTITION WALLS TO ENCLOSE/CREATE CLASSROOMS,OFF... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331061H | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED THE INSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM CONSISTING OF FIRE SPRINKLER PI... | $0 | $0 | Nov 12, 2021 |
| Apr 12, 2018 | 35331066R | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED ON FLRS 2,3,4,5 THE INSTALLATION OF BATHROOMS WITH 6 OR MORE STALLS AND STAINLESS STEE... | $0 | $0 | Nov 12, 2021 |
| Apr 12, 2018 | 35331928L | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED IN INSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM CONSISTING OF FIRE SPRINKLER PIP... | $0 | $0 | Nov 12, 2021 |
| Apr 12, 2018 | 35331071L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF SYSTEM OF AUTOMATIC FIRE SPRINKLER SYSTEM WHERE REQUIRE... | $2,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331068K | RESOLVE | CLASS - 1 | FGC403.8/MISCELLANEOUS VIOLATIONS GAS PIPING NOT PAINTED TO PROTECT ITFROM THE ELEMENTS AND CORROSION.OBSERVED ON 2 F... | $6,250 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331067Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON THE 5TH FLR NINE URINAL DRAINS OPEN AND THEREBY ALL... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331065P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON FLR 2,3,4,5 NO PRESSURE GAUGES INSTALLED AT FLOOR C... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331064N | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED INBOILER ROOM ON 5TH FLR A BOILER AND STORAGE TANK INSTALLED WITH GAS,WATER AND FLUE P... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331063L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 6TH FLR NO INSPECTORS TEST VALVE INSTALLED ON THE A... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331047L | RESOLVE | CLASS - 2 | FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OBSERVED IN BASEMENT AREA MC CABLES,GREEN... | $2,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331039L | RESOLVE | CLASS - 2 | EC408.4/FAILURE TO PROVIDE CIRCUIT DIRECTORY OR IDENTIFICATION.OBSERVED THROUGHOUT BUILDING ELECRICAL PANELS WITHOUT ... | $2,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331038J | RESOLVE | CLASS - 1 | FAILURE TO PROTECT TEMPORARY WIRING FROM IMPROPER CONTACT.OBSERVED IN BASEMENT AREA THE INSTALLATION OF ROMEX-TYPE TE... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331037H | RESOLVE | CLASS - 1 | FAILURE TO GROUND ELECTRICAL SYSTEMS.OBSERVED ON THE ROOF TOP AREA ABOVE SUPERMARKET THE INSTALLATION OF EXPOSED COND... | $12,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331036X | RESOLVE | CLASS - 1 | EC300.4/FAILURE TO PROTECT CONDUCTORS FROM PHYSICAL DAMAGE.OBSERVED CONDUCTORS ON ROOFTOP OF SUPERMARKET NOT PROTECTE... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331035Y | RESOLVE | CLASS - 1 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS DEVICES,APPLIANCES OR WIRING IN USE.OBSERVED ON... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310923J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE PROOFINGNOTED;OBSERVED ON CELLAR FLOOR NEWLY INSTALLED ... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310910K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.FAILURE TO PROV-IDE NUMBER OF REQUIRED MEANS OF EGRESS FOR EVER... | $6,250 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310909N | RESOLVE | CLASS - 1 | FAILURE TO MAINTIAN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT THE 6TH FLOOR OF THE PREMISES A SYNOGOGUE WITH FEW ... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331031R | RESOLVE | CLASS - 1 | FAILURE TO PROTECT TEMPORARY WIRING FROM IMPROPER CONTACT.OBSERVED IN BASEMENT AREA THE INSTALLATION OF ROMEN-TYPE TE... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310922H | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY TEH CERTIFICATE OF OCCUPANCY OR BUILDING DEPT. RECORDS.NOTED,BUILDING DEPARTMEN... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310921X | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICTE OF OCCUPANCY OR BUILDING DEPT.RECORDS,NOTED;CERTIFICATE OF OCCUP... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310920Y | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS NOTED ON GROUND LEV... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310919R | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED: DEPARTMENT O... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310915J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE STOPPINGPER BC 712.3;27-345.OBSERVED AT 1 TO 5TH FLOOR ... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331929N | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED IN ROOM 402,405,411 & 412 GAS FIRED HEATING UNITS INSTALLED WITH FLUE AND GAS PIPING W... | $0 | $0 | Jun 5, 2019 |
| Apr 12, 2018 | 35331926H | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED ON THE 2,3,4 AND 5 FLRS THE INSTALLATION OF BATHROOMS WITH SIX OR MORE STALLS AND STAI... | $0 | $0 | Jun 5, 2019 |
| Apr 12, 2018 | 35310908L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 4TH FLOOR AND 3RD FLOOR STAIRCASE HAS MULTIPLE CRAC... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310924L | RESOLVE | CLASS - 1 | FAILURE TO MAINTIAN BUILDING IN CODE COMPLIANT MANNER.NO FIRE PROOFINGNOTED.OBSERVED ON CELLAR FLOOR NEWLY INSTALLED ... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35310925N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NO FIRE PROOFINGNOTED.OBSERVED ON STAIRCASE A & ON 2ND FLOOR FR... | $12,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331042M | RESOLVE | CLASS - 1 | FAILURE TO PROTECT TEMPORARY WIRING AGAINST IMPROPER CONTACT PER SECTION.OBSERVED THROUGHOUT BASEMENT AREA,THE INSTAL... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331045H | RESOLVE | CLASS - 1 | FAILURE TO PROTECT TEMPORARY WIRING FROM IMPROPER CONTACT.OBSERVED IN BASEMENT AREA THE INSTALLATION OF ROMEX TYPE TE... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331074R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED IN CELLAR PVC PIPING AND MATERIALS USED ON THE DWV SYS... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331930K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED IN CELLAR ELECTRONIC TAMPER PROOF VALVES ON THE AUTOMA... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331927J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF A SYSTEMOF AUTOMATIC FIRE SPRINKLER SYSTEM WHERE REQUIR... | $2,500 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331073P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.FAILURE TO COMPLY WITH THE LAW FOR DRAINAGE SYSTEMS PER PC702.1... | $1,562 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331070J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 3RD FLR A COMMERCIAL STOVE BEING SUPPLIED GAS WIHA ... | $3,125 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331069M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON OUTSIDE WALL OF KITCHEN ON TH 3RD FLR THE EXHAUST F... | $3,125 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331060X | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT.OBSERVED THE INSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM CONSISTING OF FIRE SPRINKLER PI... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331049P | RESOLVE | CLASS - 2 | FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OSERVED IN BASEMENT AREA ME CABLES & COND... | $2,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331048N | RESOLVE | CLASS - 2 | FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OBSERVED IN BASEMENT AREA MC CABLES HANGI... | $2,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331044X | RESOLVE | CLASS - 2 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED ON ROOFTOP ARE INSTALLATION OF SPLIT-AC SYSTEM & ASSOCIATED WIRING,DISCONNE... | $2,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331043Y | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT.OBSERVED ON FLOOR 2 THRU 5 INSTALLATION OF BRANCH CIRCUIT WIRING,RACEWAYS LIGHTS REC... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331041K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE/MAINTAINA ACCESS/WORK SPACE ABOUT ELECTRICAL EQUIPMENT.OBSERVED IN VARIOUS ROOMS LABELED LUNCROOM ... | $1,250 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331040Z | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT.OSERVED ON FLOORS 2-5 INSTALLATION OFBRANCH CKL WIRING,ELECTRICAL RACEWYS,LIGHTS,REC... | $4,000 | $0 | Jul 23, 2018 |
| Apr 12, 2018 | 35331033K | RESOLVE | CLASS - 2 | FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLES/BOXES CABINETS/FITTINGS.OBSERVED ON 5TH FLR AREA MC CABLES,CONDUIT... | $2,000 | $0 | Jul 23, 2018 |